//Verison=2.2
//Example,Don't Delete flowing text!
//Button NIMI // Generator NIMI 
//Button NIMI 100 // Generator NIMI and Delay 100ms, 100 not is nessary
//Button INT0 // Generator INT0 and Delay 200ms
//Button RESETAMBE3000
//Button RESET3252
//Send 1 command, Receive 2 response with one is not verify.
//Command ID: CARRIER_LOST // necessary!
//Summary  // not essential, 
//Send command: 61 00 02 00 19 00 // necessary!
//Pause=300 // not essential, unit: ms; Pause 300ms after Send command
//Timeout=100 // not essential, unit: ms; if not receive '84 A9 61 ...' in 100ms after send command, Timeout error will happen!
//*Receive Data: 61 00 02 51 19 00 // not essential, receive but not verify
//Receive Data: 61 00 02 51 19 20 // not essential, receive and verify 
//.Set x = AA B0  -- Define var x ; Added in ver2.2
// ... 61 00 02 00 19 {x}   --- use the defined var, The {x} will be replaced with AA B0 
//

Command ID:	NXDN_CALL_OPTION
Send	Command: 84 A9 61 00 06 06 47 82 00 00 00 00
Receive Data:   84 A9 61 00 02 06 47 00
Pause 1000
Command ID:	WORK_MODE_TX
Send	Command: 84 A9 61 00 04 00 18 03 00 00
Receive	Data:84 A9 61 00 02 00 18 00
Command ID:	PROCESS_MODE
Send	Command: 84 A9 61 00 02 00 1A 02
Receive	Data:84 A9 61 00 02 00 1A 00
Pause 1000

Command ID:	NXDN_DATA_FRAME
Send command: 84 a9 61 00 13 00 43 00 00 0f 10 81 00 00 00 20 03 88 93 90 00 00 00 00 00
Receive Data: 84 a9 61 00 01 20 43

Command ID:   NXDN_DATA_FRAME
Send command: 84 a9 61 00 09 00 43 00 00 05 8C 81 00 00 00
Receive Data: 84 a9 61 00 01 20 43

Receive	Data:84 A9 61 00 13 20 43 E0 00 0F 10 81 00 00 00 20 03 88 93 90 00 00 00 00 00
Receive	Data:84 A9 61 00 09 20 43 C0 00 05 8C 81 00 00 00